Room automation
Build room-by-room climate, airflow, CO₂, lighting and irrigation recipes around your process.

Programmable industrial hardware · Professional cultivation
Connect sensors, cameras, lights, pumps, HVAC and doors. Then use AI and code to decide how they work together.
First, the hardware
Brain is a physical industrial cabinet. Your electricians connect the facility. Your team builds the application, operating logic and AI on top of documented interfaces.

Sensors and equipment in one system
Climate, water, energy, cameras, doors and existing systems
Industrial I/O, local compute, firmware, permissions and diagnostics
Lights, pumps, valves, HVAC, alarms and approved equipment
Once connected, Brain can become the controller, tracking tool, security workflow or facility application your team creates.
Possibilities, built by you
These are examples of what a customer could create. Brain is not a locked cultivation or compliance product.
Build room-by-room climate, airflow, CO₂, lighting and irrigation recipes around your process.
Use PoE cameras and the included NVIDIA Jetson for your own growth, uniformity or anomaly models.
Connect identifiers, events and facility data to a tracking application designed by your team.
Build jurisdiction-specific records, approvals and system integrations without treating the hardware as a compliance guarantee.
Connect approved readers, door contacts, cameras and alarms to customer-defined permissions and event workflows.
Repeat the same Brain hardware across rooms and facilities while keeping each application under your control.


BRAIN CULTIVATION PLANNER
Describe your facility, choose what Brain should control and select the level of sensing you need. The configurator separates your Interkey order, supplier purchases and project allowances into one complete cost plan.
RECOMMENDED FOR YOUR CONTROLLED INDOOR GROWING
Building the live site model
STEP 03 · SENSOR QUALITY
Start with our Professional recommendation or choose Budget and Expert independently for each measurement. These products are purchased separately from the listed external suppliers; Interkey confirms the selected connection path.
THE BRAIN PLATFORM
CompuLab SBC-IOT-iMX8Plus running the Interkey control and data platform locally.
RS-485 / Modbus RTU connects distributed sensors, meters and remote I/O across the site.
PoE cameras feed local vision models without requiring continuous cloud video upload.
Use Brain Firmware and the open integration paths to build the automation and AI your operation needs.
Wireless sensors, cameras and AI may adjust approved setpoints and modes inside configured limits. Emergency stops and critical interlocks for irrigation, heating, ventilation, dosing and fertigation remain wired.
The sensor connects to the corresponding Brain input without a protocol gateway.
A conventional industrial signal is wired to a Brain digital input.
Interkey configures the device address, register map and RS-485 network.
The displayed package price includes the interface needed to connect the device.
Interkey selects the exact variant, accessories and installation details for the site.
CONNECTION METHODS
DIRECT SENSOR PATH
WIRED DISCRETE SIGNAL
INDUSTRIAL SERIAL BUS
SYSTEM INTEGRATION
Add wireless soil, climate, level or environmental sensors where field cabling is impractical. Brain receives, timestamps and monitors every reading locally, while wired hardware remains responsible for critical actions.
Interkey supplies the correct gateway, antenna, channel plan and sensor variant for EU868, US915, AU915, AS923 and other applicable regional plans according to the installation country and local radio rules.
RAK5146-225 covers selected 8xx MHz plans and RAK5146-125 covers selected 9xx MHz plans. EU reference: approximately €101 ex VAT for the concentrator before carrier, enclosure, antenna and power accessories. DigiKey Germany, checked 18 August 2026.RAK5146 regional variants ↗A 4–20 mA or 0–10 V sensor connects through an external Modbus analog-input module or signal converter selected by Interkey.
For pH, EC, pressure, level and flow transmitters, the displayed package price includes the required converter whenever the selected reference uses an analog output.SDI-12 devices connect through an SDI-12 gateway, while IO-Link sensors connect through an IO-Link master. PROFINET, EtherNet/IP and CANopen equipment can be included through a suitable project gateway.
The purchase plan lists the required master, converter, enclosure, power and cable set so the customer sees the complete connection path and where to obtain it.Interkey converts the quantities in this configurator into the required RTD, digital I/O, switching and interface modules. The quotation includes the channel allocation, board count, cabinet layout, power distribution and terminal plan.
RECOMMENDED EQUIPMENT
The clearest documented direct sensor path: one PT100 or PT1000 measurement uses one available RTD channel.
A practical four-wire entry probe for dry or protected measurement points.
RS 348-2427Probe with 2 m lead; gland, extension cable and mounting excluded.
Source checked: RS Components, Italy, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
Industrial threaded four-wire PT100 probe with a sealed connector.
PR-24-3-100-A-G1/4-6-150Configured probe; mating cable, gland and installation hardware excluded.
Source checked: OMEGA Engineering, Germany, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
A hygienic four-wire PT100 assembly for wash-down or demanding process installations.
PRS-3-100-A-TW-0163-D1-NB9WConfigured probe and thermowell baseline; site cable and mounting accessories excluded.
Source checked: OMEGA Engineering, Germany, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
You may use another manufacturer or model when it meets the interface, electrical, measurement and environmental requirements below. Interkey confirms the final selection before ordering or commissioning.
Use an industrial Modbus RTU transmitter where a combined room or greenhouse climate point is preferred over direct RTD alone.
Compact wall transmitter for commercial climate measurement.
700757Transmitter only; power, cable and bus termination excluded.
Source checked: Thermokon Direct, Germany, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
Industrial outdoor/greenhouse transmitter with a replaceable sensing architecture.
626439Transmitter only; power, field cable, surge and mounting accessories excluded.
Source checked: Thermokon Direct, Germany, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
High-accuracy probe for continuously high humidity and demanding process environments.
HMP7 (configured Modbus probe)Configured probe reference; connection cable and mounting excluded.
Source checked: Vaisala EU Store, Finland / EU, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
You may use another manufacturer or model when it meets the interface, electrical, measurement and environmental requirements below. Interkey confirms the final selection before ordering or commissioning.
The Modbus ordering variant is preferred. An analog variant is not a direct Brain connection and needs a priced converter.
Industrial wall CO₂ transmitter with a direct Modbus variant.
1501-7110-6001-200CO₂ transmitter only; power, cable and mounting excluded.
Source checked: STEP Store, Spain, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
Combined CO₂, humidity and temperature transmitter for demanding rooms and greenhouses.
1501-7116-6001-200 / 44019330Configured transmitter only; power, cable and mounting excluded.
Source checked: Vedotec, Netherlands, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
High-performance CO₂ probe and transmitter bundle with diagnostics and display.
GMP252INDIGO202GMP252 probe and Indigo 202 transmitter bundle; field cable/mounting excluded.
Source checked: Vaisala EU Store, Finland / EU, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
You may use another manufacturer or model when it meets the interface, electrical, measurement and environmental requirements below. Interkey confirms the final selection before ordering or commissioning.
Choose the measurement principle and installation method for the crop, substrate and irrigation strategy—not only the lowest sensor price.
Low-cost multi-parameter RS-485 probe for non-critical trend measurements.
SEN0604Probe with standard cable; field junction, calibration and installation hardware excluded.
Source checked: OpenCircuit, Spain, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
Commercial TDR/FDR soil-moisture reference with a direct serial interface.
SMT100-RS485-10MSensor with 10 m cable; junction box and installation tools excluded.
Source checked: Aqua-Technik Shop, Germany, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
Research-grade root-zone sensing routed through a region-specific wireless gateway path.
TEROS 12 + Dragino SDI-12-LB regional variantTEROS 12 (€374) plus SDI-12-to-LoRaWAN converter EU price reference (€44.90); shared gateway excluded here and added once.
Source checked: ELSYS / Kilo Electronics, Sweden / Germany, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
You may use another manufacturer or model when it meets the interface, electrical, measurement and environmental requirements below. Interkey confirms the final selection before ordering or commissioning.
The complete price must include both measurements, required transmitters, calibration consumables and any analog conversion.
Two direct Modbus probes for an economical nutrient-water measurement set.
101990666 + 314990634pH probe (€149) and EC/TDS/temperature probe (€164); calibration and mounting excluded.
Source checked: ShopIoT, EU distributor, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
Industrial RS-485 probe pair with electronics close to the electrodes.
PH485-K5 + ESV11PH485-K5 (€361) and ESV11 (€808) from the 2026 EU price list; holders and calibration excluded.
Source checked: Fiedler 2026 EU price list, Czech Republic, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
Industrial pH/EC probe set with a complete priced analog-to-Modbus signal chain.
HI98143-22 + HI1001 + HI3001 + ADAM-4017+-FHI98143-22 (€614.20), HI1001 (€204), HI3001 (€260), ADAM-4017+-F (€265.60) and €50 calibration-solution allowance.
Source checked: Hanna Instruments / BMC, Sweden / Germany, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
You may use another manufacturer or model when it meets the interface, electrical, measurement and environmental requirements below. Interkey confirms the final selection before ordering or commissioning.
Select a pipe size, fluid, required accuracy and whether a threshold/pulse or a continuous engineering value is needed.
A robust threshold/monitoring device for a small liquid flow path—not a universal continuous meter.
SBY332Flow switch only; process adapters, cable and power accessories excluded.
Source checked: Automation24, Germany, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
Continuous industrial flow measurement routed through a priced IO-Link-to-Modbus TCP master.
SM7000 + AL1940SM7000 reference (€644.40) plus AL1940 (€433.80); M12 cables and process adapters excluded.
Source checked: Automation24, Germany, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
Non-invasive ultrasonic flowmeter for larger water pipes with direct Modbus output.
159300314Flowmeter baseline; mounting preparation, cable extension and commissioning excluded.
Source checked: Automation24, Germany, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
You may use another manufacturer or model when it meets the interface, electrical, measurement and environmental requirements below. Interkey confirms the final selection before ordering or commissioning.
Local measurements add site truth to regional forecast APIs. Forecasts inform approved modes and setpoints; they never replace wired safety states.
Compact all-in-one Modbus station for operational farm context.
IOT-S300WS7Sensor head only; mast, cable, power and lightning protection excluded.
Source checked: Linovision EU, EU store, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
Commercial compact station with a wired industrial interface.
WSC11 Modbus RTU variantStation head only; mast, cable, power and surge/lightning protection excluded.
Source checked: Umwelt Messtechnik, Germany, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
Professional multi-parameter station for traceable site weather and research workflows.
8370.2 + 20 m connection cableWS600-UMB (€3,270 ex VAT equivalent) and 20 m cable (€160.50 ex VAT equivalent).
Source checked: Lufft Messtechnik, Germany, 18 August 2026Open price source ↗Purchased separately from the supplier. Reference product — an equivalent compatible device may be selected after Interkey review.
You may use another manufacturer or model when it meets the interface, electrical, measurement and environmental requirements below. Interkey confirms the final selection before ordering or commissioning.
Sensor prices are external EU distributor or manufacturer references in EUR excluding VAT. The source country and check date appear on every card. The customer purchases these products separately; final price, shipping and availability are confirmed by the selected supplier.
YOUR PURCHASE PLAN
Brain and cameras come from Interkey. Sensors and other equipment are purchased separately from the listed suppliers. Values are in EUR excluding VAT.
Brain hardware, firmware, included support and the selected Interkey cameras.
Swipe for quantity and price →
| Product or equipment | Purchase from | Exact qty | Reference / unit ex VAT | Line total ex VAT |
|---|---|---|---|---|
| Interkey control platformBrain CultivationComplete industrial controller with cabinet, firmware, local Jetson vision, managed PoE and integrated power architecture · 5 hours of direct support included | InterkeySupplied with the Brain project | 1Brain | €2,500Interkey price | €2,500 |
| Vision networkManaged 20-port PoE network infrastructure1 active Brain node includes 20 managed PoE camera connections, Jetson uplink and local network segmentation. The project plan defines the PoE power budget and port allocation. | InterkeySupplied with the Brain project | 1Brain network | IncludedIn Brain price | Included |
| VisionInterkey low-light PoE room cameraRoom-rated PoE imaging set with lens, codec and lighting selected for the room | InterkeySupplied with the Brain project | €180Interkey price | €720 |
Exact reference products with supplier, country, check date and direct offer link. Interkey confirms compatibility; the customer orders separately.
Swipe for quantity and price →
| Product or equipment | Purchase from | Exact qty | Reference / unit ex VAT | Line total ex VAT |
|---|---|---|---|---|
| Climate sensingOMEGA PR-24 RTD probePR-24-3-100-A-G1/4-6-150 · 4-wire PT100 resistance · Direct Brain connection | OMEGA Engineering ↗Germany · checked 18 August 2026 | €169.42Supplier reference | €1,355 | |
| Climate sensingThermokon WSA temp_rH RS485 Modbus626439 · Modbus RTU over RS-485 · Integrated via Modbus | Thermokon Direct ↗Germany · checked 18 August 2026 | €357.9Supplier reference | €1,432 | |
| Climate sensingS+S Regeltechnik AFTM-CO2-Modbus1501-7116-6001-200 / 44019330 · Modbus RTU over RS-485 · Integrated via Modbus | Vedotec ↗Netherlands · checked 18 August 2026 | €570Supplier reference | €2,280 | |
| IrrigationTruebner SMT100-RS485, 10 m cableSMT100-RS485-10M · RS-485, Modbus/ASCII depending on configured firmware · Integrated via Modbus | Aqua-Technik Shop ↗Germany · checked 18 August 2026 | €129Supplier reference | €1,032 | |
| IrrigationFiedler PH485-K5 + ESV11 digital conductivity sensorPH485-K5 + ESV11 · Modbus RTU / documented Fiedler serial protocol over RS-485 · Integrated via Modbus | Fiedler 2026 EU price list ↗Czech Republic · checked 18 August 2026 | €1,169Supplier reference | €1,169 | |
| Irrigationifm electronic SM7000 with AL1940 IO-Link masterSM7000 + AL1940 · IO-Link to AL1940; Modbus TCP and MQTT from the master · Gateway / converter included | Automation24 ↗Germany · checked 18 August 2026 | €1,078.2Supplier reference | €4,313 |
Cabling, mounting, actuators and project-specific equipment are budget allowances until exact local offers are selected.
Swipe for quantity and price →
| Product or equipment | Purchase from | Exact qty | Planning value / unit | Line total ex VAT |
|---|---|---|---|---|
| Indoor infrastructureRoom cabling, junctions and protected distribution50 to 100 m planning allowance | Your preferred supplierEditable project allowance | €980 | ||
| ActuationHVAC, airflow and dehumidification interface setFor fans, dampers, humidification, cooling or dehumidification per room | Your preferred supplierEditable project allowance | €1,680 | ||
| Irrigation24 V irrigation valve and fittingsOne controlled branch per zone | Your preferred supplierEditable project allowance | €360 | ||
| Indoor environmentDimmable horticultural lighting allowanceEditable fixture placeholder; replace for mushroom, flowering or vertical-room design | Your preferred supplierEditable project allowance | €7,200 | ||
| Indoor environmentLighting group and dimming interfaceExternal DALI/vendor gateway or reviewed Modbus analog-output chain; no native 0-10 V Brain output is assumed | Your preferred supplierEditable project allowance | €1,120 | ||
| Indoor environmentRacks and controlled-room fitout allowanceEditable placeholder for shelving, trays and room-specific equipment | Your preferred supplierEditable project allowance | €8,800 | ||
| VisionIndoor Cat6 and mounting kitPer camera installation allowance | Your preferred supplierEditable project allowance | €180 | ||
| EnergyThree-phase power metering setMeter, current transformers and cabinet accessories | Your preferred supplierEditable project allowance | €480 | ||
| EnergyHVAC or lighting contactor interfaceFor engineered larger loads and approved safe states | Your preferred supplierEditable project allowance | €1,120 | ||
| Access and securityAccess reader, door contact and controller allowanceOne suggested access point per room or zone; exact devices follow the facility security design | Your preferred supplierEditable project allowance | €2,480 | ||
| Access and securityApproved lock, alarm and dry-contact interface setMachine-side interface allowance only; life-safety, egress and local access rules remain part of the engineered installation | Your preferred supplierEditable project allowance | €1,120 | ||
| CommissioningInstallation consumables and labelingTerminals, glands, markers and site contingency | Your preferred supplierEditable project allowance | €670 | ||
| Sensor installationCable, connector, gland and mounting setPer selected measurement point planning allowance; exact wet-area, UV, chemical and EMC construction confirmed during quotation | Your preferred supplierEditable project allowance | €928 | ||
| Sensor installationIsolated RS-485 segment, termination and 24 V distribution setPlanning allowance per 16 serial devices; includes isolation, termination and protected field power | Your preferred supplierEditable project allowance | €380 | ||
| CalibrationpH / EC calibration, cleaning and storage solution setEU planning allowance; exact fluids, traceability and replacement interval follow the selected probes | Your preferred supplierEditable project allowance | €85 |
WHAT THIS BUILD UNLOCKS
Brain supplies the hardware, firmware, safe machine interface and local Jetson. Your team owns the software, cultivation logic and AI.
Control temperature, humidity, CO₂, fresh air, circulation and dehumidification independently for mushroom, flowering or vertical growing rooms.
Combine moisture, pH, EC and flow with your own crop recipe, then control irrigation or dosing separately for every room.
Schedule lighting groups and environmental loads around crop phases, power limits, energy prices and safe equipment states.
Use low-light PoE cameras and the included Jetson for growth, contamination, uniformity or anomaly models without mandatory cloud video.
Connect approved door contacts, readers and alarm paths so your application can record access, notify operators and request permitted responses.
ENGINEERING HAND-OFF
Review your configuration before sending. This does not place an order. Interkey checks the regional variants, I/O allocation and availability before preparing a quotation.
Clear by design
No. Brain is physical industrial hardware and firmware. You build the applications, workflows and interfaces on top.
Those are possible customer-built applications. Regulatory suitability depends on your implementation, integrations and jurisdiction.
Brain is designed to connect software with approved cameras, sensors, I/O and equipment under configured permissions and engineering limits.
In professional operations where cultivation and the proposed application are lawful. Every deployment must be checked against local licensing, safety and facility requirements.
For professional use in jurisdictions where cultivation is legal. Applications shown are possible examples, not finished compliance products or legal advice. Connection methods, safety functions and equipment authority are reviewed for the real installation.